iDEA 3101
Name
iDEA 3101
Acenes Part
iDEA-3101
Display
Yes
Input Supervision
Yes
Certification
RoHS
Specifications
RoHS
* iDEA 3101 is currently undergoing software enhancements
** For immediate sales inquiries please Contact Us
at info@acenesllc.com or +1 914 233 1400
iDEA 310x series is a highly flexible and advanced controller to manage special locking arrangements of emergency doors. It is Wi-Fi, Bluetooth + Ethernet enabled. The device can be configured from a PC application, the cloud and with Bluetooth Low Energy (BLE) using iOS and Android applications.
Easily configurable
Mobile Configuration: Securely configure the device from your mobile device with BLE using dedicated free Android and iOS applications
Cloud Configuration: configure the device using the axess.ai website anytime, anywhere
Flexible and customizable
The inputs can be easily configured for multiple functions. Inputs can be configured as: open contact, closed contact, one resistor, and two resistor supervision modes. The input can also be configured as open contact or closed contact without any hardware modifications
The outputs can be mapped to different function states as required. Outputs can respond to trigger commands by other members of the cluster
Supports multiple reader types including iButton, Open Supervised Device Protocol (OSDP), and Wiegand Devices from multiple vendors
Using the PC app configuration and download, the display can be further customized to display integrators/customer’s company name, logo, support phone numbers, and others. There are a total of five visible and programmable lines
Using the PC app or via Cloud and by use of mobile Bluetooth, installers can change the input, output, and door configuration such as bypass time, alarm time, and others
iDEA has three special timers: 1. Nuisance timers (0,1,2 seconds) 2. Time delay to release (15,30 seconds) 3. Auto/manual alarm reset etc.
Easy Installation
The device can be installed by any exit door or protected area designated as ‘Special Locking’ in which locking is allowed under specific circumstances as detailed by the International Building Code (IBC) and the NFPA 101 Life Safety Codes
Interface to any Access Control
Remote monitoring and management of iDEA can be done from any stand-alone guard station, the cloud, or by interfacing to the buildings access control system. iDEA operates from 12-24V DC and has three programmable inputs as well as four programmable outputs. Outputs can be configured as dry or 1K or 1K/2K EOL supervision on board via jumpers. There is no need for external EOL resistor kits
Multiple Door Conditions
iDEA has dedicated outputs for remote Red/Green LEDs as well as 2.4” graphical display showing multiple door conditions such as, nuisance timer with graphical count down, graphical timer for remaining lock release period. Additionally, the graphical display shows status conditions of the door such as, Secured, Alarm and Held Open